自(zi)動歸零保護(hu)措施(shi):設(she)備在非合(he)閘(zha)狀(zhuang)態自(zi)動回歸零位(wei)狀態(tai);
零限啟動保護(hu):只(zhi)能調(tiao)壓(ya)器歸零後才(cai)能啟動,防止(zhi)產生(sheng)瞬態沖(chong)擊(ji)電壓(ya);
門(men)聯(lian)鎖保護(hu):高壓(ya)試驗區(qu)門(men)關閉才(cai)能啟動,打開自(zi)動斷(duan)高壓(ya),防止(zhi)人誤(wu)闖入觸電;
限(xian)位(wei)開關保護(hu):設(she)置(zhi)上(shang)下(xia)限位(wei)開關,使電壓(ya)在零和滿(man)量程範(fan)圍(wei)內(nei)試驗,調(tiao)壓(ya)過程到限位(wei)自動斷(duan)高壓(ya),防止(zhi)電壓(ya)過量(liang)程;
過壓(ya)過流(liu)保護(hu):在滿(man)量程範(fan)圍(wei)內(nei)可任意(yi)設(she)定電壓(ya)、電流(liu)的閥(fa)值,超(chao)過(guo)閥(fa)值自(zi)動斷(duan)高壓(ya);
空(kong)開(kai)斷(duan)閘(zha)保護(hu):設(she)備配置(zhi)總電源空(kong)氣(qi)開(kai)關,防止(zhi)試驗主(zhu)回路或控(kong)制回路發生(sheng)短(duan)路過(guo)載且(qie)過流、過(guo)壓(ya)等保護(hu)措施(shi)失靈(ling)時(shi),能有(you)效切(qie)斷(duan)電源;
保險(xian)絲(si)過載(zai)熔斷(duan)保護(hu)措施(shi):試驗控(kong)制回路配(pei)置(zhi)保險(xian)絲(si),在控(kong)制系(xi)統(tong)發生(sheng)短(duan)路故(gu)障(zhang)等情(qing)況時(shi),能有(you)效熔(rong)斷(duan)控(kong)制回路電源;
急(ji)停(ting)按鈕:設(she)備配置(zhi)急(ji)停(ting)按鈕,防止發生(sheng)著(zhe)火等危(wei)險(xian)情況(kuang)時(shi)能快速有(you)效切(qie)斷(duan)試驗回路電源;
高壓(ya)警(jing)示(shi)燈(deng):合(he)閘(zha)後警(jing)示(shi)燈(deng)亮起,提(ti)示(shi)有(you)高壓(ya),,斷(duan)閘(zha)後熄滅,起警(jing)示(shi)作(zuo)用;
屏(ping)蔽(bi)隔(ge)離(li)網(wang):試驗操作(zuo)臺與(yu)高壓(ya)設(she)備組件用屏(ping)蔽(bi)網(wang)隔(ge)離(li),防止(zhi)高壓(ya)飛弧(hu)擊(ji)傷(shang);
腳(jiao)踏(ta)防(fang)護(hu)開關:踏下(xia)可正(zheng)常(chang)升(sheng)壓(ya)試驗,擡(tai)起(qi)主(zhu)電源切(qie)斷(duan)同時(shi)調(tiao)壓(ya)器回零;
自動放電裝(zhuang)置(zhi):高壓(ya)斷(duan)閘(zha)狀(zhuang)態自(zi)動放電、合(he)閘(zha)瞬(shun)間自(zi)動斷(duan)開(kai)。